Case Report of False-Negative Diffusion-Weighted Image of Brain Magnetic Resonance Imaging (MRI) in Acute Ischemic Stroke

Wei-Lun Chang, Ji-Ching Lai, Rong-Fu Chen, Han-Hwa Hu, Chau-Shiung Pan

(Department of Neurology, Chang Hua Show Chwan Memorial Hospital, Changhua, Taiwan)

Am J Case Rep 2017; 18:76-79

DOI: 10.12659/AJCR.901691


BACKGROUND: Acute ischemic stroke is a major cause of mortality and morbidity in Taiwan. Diffusion-weighted image (DWI) is a sensitive and common strategy use for imaging acute ischemic stroke.
CASE REPORT: We present a case of a negative DWI MRI for detecting acute ischemic stroke in a clinical setting. A 75-year-old male had a DWI performed after onset of symptoms suggesting acute ischemic stroke. The initial DWI result was negative within 72 hours of presentation. The neurological symptoms of the patient persisted and DWI was repeated. After 14 days, the DWI data confirmed and demonstrated an acute ischemic stroke. The delay in DWI confirmation, from symptom onset until DWI diagnosis, was 336 hours.
CONCLUSIONS: DWI may not have 100% sensitivity and accuracy in early stages of acute ischemic stroke. The time course to the development of abnormalities detected by DWI may be longer time than anticipated.

This paper has been published under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially.