14 October 2021>: Articles
Neglected Posterior Dislocation Septic Loosening and Prolonged Flexion Contracture of Total Knee Arthroplasty: A Case Report
Patient complains / malpractice
Vasileios Athanasiou A* , Andreas Panagopoulos C , John Gliatis C , Nikolaos Papathanasiou B , Minos Tyllianakis A , Panagiotis Megas ADOI: 10.12659/AJCR.931857
Am J Case Rep 2021; 22:e931857
Figure 2. (A) Intraoperative photo after implants removal demonstrating marked bone loss especially in the femur. (B) Preparation of the intramedullary cemented rod. (C) Intraoperative photo after the application of the rod and bone-cemented cubes just prior to the application of the rest static spacer. (D) Postoperative anteroposterior and lateral radiographs after first-stage revision, showing good knee alignment.