Telescopic Corsair in 5F Guidion for Retrograde Recanalization of Complex Chronic Total Occlusions (CTOs)
Unusual setting of medical care, Educational Purpose (only if useful for a systematic review or synthesis)
Pieter-Jan Palmers12AE*, Joren Maeremans13A, Markus Meyer-Gessner4B, Yoann Bataille5B, Joseph Dens1ABEDOI: 10.12659/AJCR.902560
Am J Case Rep 2017; 18:472-477
Abstract
BACKGROUND: Retrograde advancement of microcatheters through septal/epicardial connectors can be challenging. Although several tricks might help to do so (e.g., balloon trap of retro wire in second guiding, balloon trap of retro wire in native coronary artery, and use of antegrade extension to approximate the antegrade conduit to the retrograde gear), these tricks cannot always be applied, especially in patients with poor access. Also, puncturing, knuckling, and crossing of the distal CTO cap (or the aorta as described in 1 of the cases) sometimes needs a lot of backup of the microcatheter.
CASE REPORT: We describe 3 cases in which we used a novel telescopic technique with 5F Guidion (IMDS®) supported retrograde Corsair (Asahi®) advancement in complex CTO lesions.
CONCLUSIONS: The telescopic Corsair in 5F Guidion may offer the support needed to end successfully in these situations.
Keywords: Coronary Artery Disease, coronary occlusion, percutaneous coronary intervention
In Press
Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.946041
Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.947953
Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.946932
Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.947854
Most Viewed Current Articles
21 Jun 2024 : Case report
96,778
DOI :10.12659/AJCR.944371
Am J Case Rep 2024; 25:e944371
07 Mar 2024 : Case report
52,393
DOI :10.12659/AJCR.943133
Am J Case Rep 2024; 25:e943133
20 Nov 2023 : Case report
31,818
DOI :10.12659/AJCR.941424
Am J Case Rep 2023; 24:e941424
18 Feb 2024 : Case report
23,483
DOI :10.12659/AJCR.943030
Am J Case Rep 2024; 25:e943030