07 December 2019 : Case report
Intra-Aortic Balloon Pump Catheter Insertion Using a Novel Left External Iliac Artery Approach in A Case of Chronic Heart Failure Due to Dilated Cardiomyopathy
Unusual clinical course, Challenging differential diagnosis, Diagnostic / therapeutic accidents, Unusual setting of medical care, Unexpected drug reaction, Educational Purpose (only if useful for a systematic review or synthesis)
Mirosław Dziekiewicz1AE*, Marek Banaszewski2D, Mateusz Kuć3F, Janina Stępińska2BDOI: 10.12659/AJCR.920554
Am J Case Rep 2019; 20:1826-1829
Abstract
BACKGROUND: The use of an intra-aortic balloon pump (IABP) in patients with advanced heart failure can provide interim mechanical support as a bridge to further treatment, including cardiac transplantation. The femoral artery, axillary artery, and subclavian artery are the main approaches to IABP catheter placement. A case is reported of the use of a left external iliac artery approach to IABP catheter placement using a subcutaneous channel in a patient with chronic heart failure.
CASE REPORT: A 67-year-old woman presented with a history of heart failure. She had New York Heart Association (NYHA) Functional Class IV symptoms. The patient had a history of chronic heart failure due to dilated cardiomyopathy with a left ventricular ejection fraction of 25%, severe mitral regurgitation, paroxysmal atrial fibrillation, and hypothyroidism. Immediate pharmacological treatment began, and an IABP catheter was initially inserted using femoral artery access. During 115 days of hospital treatment, several unsuccessful attempts were made to remove the IABP catheter. Due to prolonged patient immobility, the IABP catheter access was changed from the femoral artery to the external iliac artery. A prosthetic Dacron graft and a subcutaneous channel were used. Optimal pharmacotherapy commenced, and the patient underwent rehabilitation and mobilization with significant improvement in cardiac function. At 195 days after changing the IABP catheter access, the patient underwent successful heart transplantation.
CONCLUSIONS: This report demonstrated that in a patient with chronic heart failure requiring long-term femoral IABP catheter placement, an external iliac artery approach using a subcutaneous channel provided a bridge to cardiac transplantation.
Keywords: Intra-Aortic Balloon Pumping, Retroperitoneal Space, Cardiomyopathy, Dilated, Chest Pain, Dyspnea, Iliac Artery
In Press
Case report
Concurrent Diagnosis of Chronic Lymphocytic Leukemia and Plasma Cell Myeloma: Report of 2 Cases and Differe...Am J Case Rep In Press; DOI: 10.12659/AJCR.944707
Case report
“No-Touch” Saphenous Vein Grafting and Coronary Aneurysm Ligation in an Adult Patient with Suspected Prior ...Am J Case Rep In Press; DOI: 10.12659/AJCR.945431
Case report
Unexpected Chylous Ascites During Umbilical Hernia Repair in a Patient with Necrotizing Pancreatitis: A Cas...Am J Case Rep In Press; DOI: 10.12659/AJCR.944609
Case report
A Rare Complication of Cannabinoid Hyperemesis SyndromeAm J Case Rep In Press; DOI: 10.12659/AJCR.945106
Most Viewed Current Articles
21 Jun 2024 : Case report 57,146
Intracranial Parasitic Fetus in a Living Infant: A Case Study with Surgical Intervention and Prognosis Anal...DOI :10.12659/AJCR.944371
Am J Case Rep 2024; 25:e944371
07 Mar 2024 : Case report 42,303
Neurocysticercosis Presenting as Migraine in the United StatesDOI :10.12659/AJCR.943133
Am J Case Rep 2024; 25:e943133
10 Jan 2022 : Case report 32,415
A Report on the First 7 Sequential Patients Treated Within the C-Reactive Protein Apheresis in COVID (CACOV...DOI :10.12659/AJCR.935263
Am J Case Rep 2022; 23:e935263
23 Feb 2022 : Case report 19,841
Penile Necrosis Associated with Local Intravenous Injection of CocaineDOI :10.12659/AJCR.935250
Am J Case Rep 2022; 23:e935250