[In Press] Novel Ramp Test to Optimize Pressure Setting of Adaptive Servo-Ventilation Using Non-Invasive Lung Fluid Level Quantification
Unusual clinical course, Challenging differential diagnosis, Unusual or unexpected effect of treatment, Diagnostic / therapeutic accidents, Unexpected drug reaction , Educational Purpose (only if useful for a systematic review or synthesis)
Masakau Hori1BC, Teruhiko Imamura
DOI: 10.12659/AJCR.935086
Am J Case Rep In Press; DOI: 10.12659/AJCR.935086
Available online: 2022-06-08, In Press, Corrected Proof
Publication in the "In-Press" formula aims at speeding up the public availability of the pending manuscript while waiting for the final publication. The assigned DOI number is active and citable. The availability of the article in the Medline, PubMed and PMC databases as well as Web of Science will be obtained after the final publication according to the journal schedule
Abstract
BACKGROUND
Optimal patient selection and device pressure settings are key to successful adaptive servo-ventilation therapy, but there is no established strategy thus far. Adaptive servo-ventilation therapy at an inappropriately high pressure setting for those without pulmonary congestion decreases cardiac output and worsens clinical outcomes. The remote dielectric sensing system (ReDS) is a novel noninvasive tool to estimate the lung fluid amount. The ReDS might be a promising tool for successful adaptive servo-ventilation therapy if appropriately utilized for optimal patient selection and device pressure setting.
CASE REPORT
An 83-year-old woman was admitted to our hospital to treat acute decompensated heart failure with preserved ejection fraction that was refractory to conventional medical therapy. Following the confirmation that she had significant pulmonary congestion with 47% of the ReDS value (normal range, 20-35%), we performed a “ramp test” to optimize device pressure, by measuring ReDS values and noninvasively estimating the cardiac output and stroke volume at each pressure setting. The device pressure setting was finally determined to minimize pulmonary congestion and maximize cardiac output. Following the continuous adaptive servo-ventilation therapy with the optimized pressure setting, the patient’s hospitalization was uneventful and she was discharged.
CONCLUSIONS
We propose performing a ramp test to optimize the pressure setting of adaptive servo-ventilation by utilizing ReDS technology for each patient, instead of using a default or inappropriately higher pressure setting. However, further studies including large patient populations are warranted to validate the prognostic implication of this customized ramp test protocol.
Keywords: Heart Failure; Hemodynamics; Pulmonary Edema
SARS-CoV-2/COVID-19
16 June 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936498
13 June 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936889
13 June 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936128
03 June 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936832
In Press
24 Jun 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936288
24 Jun 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936641
24 Jun 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936513
22 Jun 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936862
Most Viewed Current Articles
23 Feb 2022 : Case report
DOI :10.12659/AJCR.935250
Am J Case Rep 2022; 23:e935250
17 Feb 2022 : Case report
DOI :10.12659/AJCR.934399
Am J Case Rep 2022; 23:e934399
06 Dec 2021 : Case report
DOI :10.12659/AJCR.934406
Am J Case Rep 2021; 22:e934406
09 Feb 2022 : Case report
DOI :10.12659/AJCR.934744
Am J Case Rep 2022; 23:e934744