15 June 2022
: Case report
[In Press] Intravascular Catheter Accidentally Placed into the Right Lumbar Vein from the Right Femoral Vein: A Case Report
Unusual clinical course, Challenging differential diagnosis, Unusual or unexpected effect of treatment, Diagnostic / therapeutic accidents, Unexpected drug reaction , Clinical situation which can not be reproduced for ethical reasons
Yo Ishihara1ABCDEF, Hiroyuki Fukui2ADEF, Kiyomitsu Fukaguchi
DOI: 10.12659/AJCR.936275
Am J Case Rep In Press; DOI: 10.12659/AJCR.936275
Available online: 2022-06-15, In Press, Corrected Proof
Publication in the "In-Press" formula aims at speeding up the public availability of the pending manuscript while waiting for the final publication. The assigned DOI number is active and citable. The availability of the article in the Medline, PubMed and PMC databases as well as Web of Science will be obtained after the final publication according to the journal schedule
Abstract
BACKGROUND
Severe hypothermia has a high mortality rate and necessitates aggressive warming to save lives. One of the most effective treatments for severe hypothermia is intravascular rewarming. Intravascular recuperative warming can be delivered by inserting a catheter through the cervical or femoral veins. Catheter insertion through the femoral vein is a commonly performed procedure with fewer complications than catheter insertion through the internal jugular vein. This procedure is commonly conducted by inserting a central venous catheter through the femoral vein. When a catheter is inserted through the femoral vein, a frontal abdominal radiograph is often used to confirm the position of the catheter tip.
CASE REPORT
We present the case of a 58-year-old Japanese man who had severe hypothermia. Under ultrasound guidance, a catheter was inserted through the femoral vein into the inferior vena cava for active rewarming. A frontal abdominal radiograph showed that a catheter tip appeared to be in the inferior vena cava. However, a subsequent computed tomography scan revealed that the catheter tip had been misplaced into the right ascending lumbar vein.
CONCLUSIONS
Catheters may stray into the right ascending lumbar vein if they are placed through the right femoral vein. Frontal abdominal radiographs may be insufficient to confirm catheter placement.
Keywords: Catheterization; Femoral Vein; Radiography, Abdominal
SARS-CoV-2/COVID-19
16 June 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936498
13 June 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936889
13 June 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936128
03 June 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936832
In Press
24 Jun 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936288
24 Jun 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936641
24 Jun 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936513
22 Jun 2022 : Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.936862
Most Viewed Current Articles
23 Feb 2022 : Case report
DOI :10.12659/AJCR.935250
Am J Case Rep 2022; 23:e935250
17 Feb 2022 : Case report
DOI :10.12659/AJCR.934399
Am J Case Rep 2022; 23:e934399
06 Dec 2021 : Case report
DOI :10.12659/AJCR.934406
Am J Case Rep 2021; 22:e934406
09 Feb 2022 : Case report
DOI :10.12659/AJCR.934744
Am J Case Rep 2022; 23:e934744