Publication in the "In-Press" formula aims at speeding up the public availability of the pending manuscript while waiting for the final publication. The assigned DOI number is active and citable. The availability of the article in the Medline, PubMed and PMC databases as well as Web of Science will be obtained after the final publication according to the journal schedule
Abstract
BACKGROUND
Lupus anticoagulants (LA) can interfere with routine coagulation tests such as the activated partial thromboplastin time (aPTT) and prothrombin time (PT). The international normalized ratio (INR) is derived from PT and is used to monitor warfarin therapy. A positive LA result is one of the laboratory criteria of the 2023 ACR/EULAR antiphospholipid syndrome (APS) classification criteria. We report a case in which LA interfered with INR measurement in an APS patient.
CASE REPORT
Our patient was a 45-year-old man who had experienced multiple episodes of thromboembolism. His INR was consistently high, despite not being on any anticoagulant. Our laboratory used a recombinant PT reagent, Siemens Healthineers Dade® Innovin® on a fully automated coagulometer, the Sysmex CS-2500. PT measurements were repeated using 2 different analyzers, the Sysmex CA-104 and Werfen ACL Top 550 CTS. The PT results were 40.5 s (reference range (RR): 9.3-10.8 s) and 56 s, using Sysmex CS2500 and CS104, respectively. However, the PT was 13.4 s (RI: 10.3-12.7 s) using Werfen ACL Top 550 CTS. We retested the sample using Thromborel® S, a tissue-derived PT reagent, and PT was found to be within the reference range. The patient tested positive for LA, anti-cardiolipin, and anti-beta2 glycoprotein I antibodies.
CONCLUSIONS
LA can falsely prolong the PT when a recombinant PT reagent is used. When we retested the plasma using a tissue-derived PT reagent – Thromborel® S – PT was within normal limits. Thus, it is important to acknowledge that LA can react differently with different PT reagents.
Keywords: Antiphospholipid Syndrome; Lupus Coagulation Inhibitor; Prothrombin Time
In Press
Case report
Post-Transplant Lymphoproliferative Disorder at the Porta Hepatis Causing Hepatic Artery Stenosis and Chole...Am J Case Rep In Press; DOI: 10.12659/AJCR.945837
Case report
Dual Blood Purification with CytoSorb and oXiris in Managing Recurrent Septic Shock: A Case ReportAm J Case Rep In Press; DOI: 10.12659/AJCR.945952
Case report
Preserving Cervical Mobility: A Novel Robot-Assisted Approach for Atlas Fracture FixationAm J Case Rep In Press; DOI: 10.12659/AJCR.945718
Case report
Neonatal Familiar Cleidocranial Dysplasia: A Case ReportAm J Case Rep In Press; DOI: 10.12659/AJCR.946322
Most Viewed Current Articles
21 Jun 2024 : Case report 82,334
Intracranial Parasitic Fetus in a Living Infant: A Case Study with Surgical Intervention and Prognosis Anal...DOI :10.12659/AJCR.944371
Am J Case Rep 2024; 25:e944371
07 Mar 2024 : Case report 48,898
Neurocysticercosis Presenting as Migraine in the United StatesDOI :10.12659/AJCR.943133
Am J Case Rep 2024; 25:e943133
20 Nov 2023 : Case report 23,170
Azithromycin Treatment for Acne Vulgaris: A Case Report on the Risk of Clostridioides difficile InfectionDOI :10.12659/AJCR.941424
Am J Case Rep 2023; 24:e941424
18 Feb 2024 : Case report 21,974
A Case of Thoracic Empyema Caused by Actinomyces naeslundiiDOI :10.12659/AJCR.943030
Am J Case Rep 2024; 25:e943030