04 January 2024 : Case report  Belgium

Innovative Approach to Difficult Airway Management: Utilizing the Cook® Airway Exchange Catheter for Double-Lumen Tube Intubation

Unusual setting of medical care

Adrien Maseri ORCID logo1ABCDEF*, Pierre Ista1ABCDEF, Gaspard Leclercq1BE, Quentin Delhez1E, Anne-Sophie Dincq ORCID logo1DEF

DOI: 10.12659/AJCR.942288

Am J Case Rep 2024; 25:e942288

Table 1. Comparison of the external diameter of the Cook® Airway Exchange Catheter with the internal and external diameter of the double-lumen endotracheal tube from Covidien® (Dublin, Ireland).

Double-Lumen TubeCook® Airway Exchanger Catheter
External diameter (Fr*)External diameter (mm**)Internal diameter (mm)External diameter (Fr)External diameter (mm)
13.75.44.67
13.05.3
12.35.1
11.74.83.67
10.73.42.67
Fr* – French (1-French=1/3 mm; 3-Fr=1 mm); mm** – millimeter.

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.