Publication in the "In-Press" formula aims at speeding up the public availability of the pending manuscript while waiting for the final publication. The assigned DOI number is active and citable. The availability of the article in the Medline, PubMed and PMC databases as well as Web of Science will be obtained after the final publication according to the journal schedule
Abstract
BACKGROUND
This report describes an incremental design refinement of the implant-crown-retained removable partial denture (ICRPD) for maxillary edentulous rehabilitation, comprising a non-cross-arch configuration with segmented short-span splinted crowns and occlusal-rest-free ring clasps.
CASE REPORT
A 61-year-old man presented with maxillary edentulism and dissatisfaction with his previous removable partial denture, which he had worn for 2 years with progressively deteriorating retention. Clinical and radiographic examinations revealed partial edentulism and chronic periodontitis. After initial periodontal therapy, teeth #13, #14, and #23 were extracted; implants were placed at sites #13, #14, #23, and #24. Following osseointegration, an ICRPD was fabricated using short-span splinted implant crowns and pure titanium ring clasps without occlusal rests. The prosthesis provided retention through implant crowns with combined implant-mucosal support. At the 4-year follow-up, probing depths were 1 to 3 mm without bleeding on probing. The patient reported high satisfaction; the OHIP-EDENT score (Chinese version) decreased from 5 to 2, and the visual analog scale pain score decreased from 3 to 0. Radiographic assessment showed marginal bone loss of 0.16 to 1.67 mm. Cone-beam computed tomography confirmed stable marginal bone levels. No biological or mechanical complications were observed.
CONCLUSIONS
This case demonstrates that the refined ICRPD design, incorporating occlusal-rest-free ring clasps and short-span splinted crowns, provided reliable retention and long-term stability over 4 years, without mechanical complications and with high patient satisfaction. These findings support the clinical feasibility of this design, which may represent a promising option for appropriately selected patients; it is hypothesized to reduce the prosthetic span and limit unfavorable load transmission to the implant necks.
Keywords: Case Reports; Dental Implantation; Denture Design; Denture, Partial, Removable
In Press
Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.953655
Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.954556
Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.953979
Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.954544
Most Viewed Current Articles
07 Dec 2021 : Case report
28,713,850
DOI :10.12659/AJCR.934347
Am J Case Rep 2021; 22:e934347
06 Dec 2021 : Case report
181,229
DOI :10.12659/AJCR.934406
Am J Case Rep 2021; 22:e934406
21 Jun 2024 : Case report
124,794
DOI :10.12659/AJCR.944371
Am J Case Rep 2024; 25:e944371
08 May 2026 : Case report
96,602
DOI :10.12659/AJCR.952158
Am J Case Rep 2026; 27:e952158