21 October 2026
: Case report
[In Press] Tibial Post Fracture in a Posterior-Stabilized Knee Prosthesis: A Case Report and Review of the Literature
Unusual clinical course, Challenging differential diagnosis, Diagnostic / therapeutic accidents
César Abraham Ávila Lozano1ACEG, César Alejandro Jiménez-ArocheDOI: 10.12659/AJCR.954794
Am J Case Rep In Press; DOI: 10.12659/AJCR.954794
Available online: 2026-10-21, In Press, Corrected Proof
Publication in the "In-Press" formula aims at speeding up the public availability of the pending manuscript while waiting for the final publication. The assigned DOI number is active and citable. The availability of the article in the Medline, PubMed and PMC databases as well as Web of Science will be obtained after the final publication according to the journal schedule
Abstract
BACKGROUND
Tibial post fracture is an uncommon but likely underrecognized complication of posterior-stabilized (PS) total knee arthroplasty (TKA) that often remains undiagnosed because conventional radiographs may be unrevealing. We report a late tibial post fracture in a previously well-functioning PS TKA, highlighting the role of dynamic fluoroscopy in raising preoperative suspicion and the successful use of isolated polyethylene insert exchange in a carefully selected patient.
CASE REPORT
A 92-year-old man presented with acute mechanical pain, recurrent clicking, and subjective instability 16 years after primary PS TKA following a low-energy flexion-rotation movement. Plain radiographs showed no evidence of periprosthetic fracture, component loosening, or implant failure. Dynamic fluoroscopy during flexion, which reproduced the patient’s symptoms, demonstrated abnormal anterior translation of the femoral component relative to the tibial insert during knee flexion, raising suspicion of cam-post mechanism failure. Revision surgery confirmed a fracture of the polyethylene tibial post with chronic wear at its base; the metallic components remained well fixed, without gross malposition. Isolated polyethylene insert exchange with a thicker insert restored intraoperative stability. At 4.5 months postoperatively, the patient demonstrated complete resolution of mechanical symptoms, with full extension, 100° to 110° of flexion, and preserved varus-valgus and anteroposterior stability.
CONCLUSIONS
This case illustrates how dynamic fluoroscopy may raise preoperative suspicion of tibial post fracture in selected patients with symptomatic late PS TKA and inconclusive conventional radiographs. In our patient, isolated polyethylene insert exchange was effective after confirmation of preserved component fixation, alignment, and overall stability, supporting its use in appropriately selected cases.
Keywords: Case Management; Case Reports; Knee; Knee Prosthesis; Tibial Fractures
In Press
Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.954143
Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.953367
Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.953942
Case report
Am J Case Rep In Press; DOI: 10.12659/AJCR.954794
Most Viewed Current Articles
07 Dec 2021 : Case report
28,713,542
DOI :10.12659/AJCR.934347
Am J Case Rep 2021; 22:e934347
06 Dec 2021 : Case report
181,019
DOI :10.12659/AJCR.934406
Am J Case Rep 2021; 22:e934406
21 Jun 2024 : Case report
124,639
DOI :10.12659/AJCR.944371
Am J Case Rep 2024; 25:e944371
08 May 2026 : Case report
96,043
DOI :10.12659/AJCR.952158
Am J Case Rep 2026; 27:e952158